Описание

HENGSTLER's H-463 safety relay is used wherever a high number of switching actions is required at moderate switching loads. H-463 safety relays conform to EN 50205 standard, Application type A, and IEC EN 61810-1.
  • 4 contacts
  • max. 6 A switching & permanent current
  • Drive is monostable as DC
  • Ambient temperature -25 to +80 °C
  • With forcibly guided contacts to EN 50205, application type A
  • CSA and TUV approval
Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family463
Contactsetforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered with Sn 100
Approval
  • TUV
  • CSA
Standards
  • EN 50205
  • IEC 61810-1
Meets the requirementsRoHS
Number of NO contacts2 ... 3
Number of NC contacts1 ... 2
Number of CO contacts0
Dimensions L x W x H [mm]
  • dustproof: 42,7 x 16,0 x 38,8 mm
  • washtight: 42,7 x 16,0 x 39,9 mm
Housing
  • dustproof (RT II)
  • washtight (RT III)
Shock resistance NO / NC [g]15/15 g
Puls duration (half sinus)11 ms
Vibration resistance NO / NC [g]1,5/1,5 g
Frequency range [Hz]10 - 150 Hz
Operating time NC contact, contact opens [ms] 10 ms
Operating time NO contact, contact closes [ms] 14 ms
Releasing time NO contact, contact opens [ms] 3,5 ms
Releasing time NC contact, contact closes [ms] 4,5 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection typeSolder pins for pcb
Weight [g]50 g
Drive system DC monostable
Nominal coil voltage [V]5 ... 220 V
Coil resistance [Ohm]12 ... 50,000 Ohm
Contact material
  • AgCdO + 0,2 ... 5 µm Au
  • AgSnO + 0,2 ... 5 µm Au
Max. switching current [A]6 A
Max. switching voltage [V]230/240 V
Max. switching capacity [VA]1200 VA
Switching capacity AC-15 at 230 V [Ie in A]1,5 A
Switching capacity DC-13 at 24 V [Ie in A]2 A
Electrical service life (with nominal load)100,000 cycles
Short-circuit capacity 1000 A / AC 230 V [A]6 A
InsulationBasic insulation
Function / ApplicationSafety relay
Product lineHENGSTLER
Relay family463
Contactsetforcibly guided
According EN 50205Application type A
Ambient temperature [°C]-25 ... +80 °C
Soldering heat resistance [°C]260 °C
Max. soldering time [s]5 s
Pins pre-soldered with Sn 100
Approval
  • TUV
  • CSA
Standards
  • EN 50205
  • IEC 61810-1
Meets the requirementsRoHS
Number of NO contacts2 ... 3
Number of NC contacts1 ... 2
Number of CO contacts0
Dimensions L x W x H [mm]
  • dustproof: 42,7 x 16,0 x 38,8 mm
  • washtight: 42,7 x 16,0 x 39,9 mm
Housing
  • dustproof (RT II)
  • washtight (RT III)
Shock resistance NO / NC [g]15/15 g
Puls duration (half sinus)11 ms
Vibration resistance NO / NC [g]1,5/1,5 g
Frequency range [Hz]10 - 150 Hz
Operating time NC contact, contact opens [ms] 10 ms
Operating time NO contact, contact closes [ms] 14 ms
Releasing time NO contact, contact opens [ms] 3,5 ms
Releasing time NC contact, contact closes [ms] 4,5 ms
Mechanical service life (without load)10,000,000 switching cycles
Connection typeSolder pins for pcb
Weight [g]50 g
Drive system DC monostable
Nominal coil voltage [V]5 ... 220 V
Coil resistance [Ohm]12 ... 50,000 Ohm
Contact material
  • AgCdO + 0,2 ... 5 µm Au
  • AgSnO + 0,2 ... 5 µm Au
Max. switching current [A]6 A
Max. switching voltage [V]230/240 V
Max. switching capacity [VA]1200 VA
Switching capacity AC-15 at 230 V [Ie in A]1,5 A
Switching capacity DC-13 at 24 V [Ie in A]2 A
Electrical service life (with nominal load)100,000 cycles
Short-circuit capacity 1000 A / AC 230 V [A]6 A
InsulationBasic insulation
''